6.2.6 Reset function
Factory setting reset.
When the balance is switched off, press the OFF -key and keep it pressed
Do not release the OFF -key. Press also the ON/TARE-key and keep it pressed
Keep the ON/TARE-key pressed, however release the OFF -key
Press OFF -key anew
Keep both keys pressed until in the displaytr” appears
Release both keys. The balance is situated in the menu.
Press the ON/TARE-key until „rSt“ appears
Confirm with the OFF key
Press the ON/TAREkey to switch among the settings:
Display Mode
„rst“ YES
Factory setting reset
„rst“ NO
No factory setting reset
Confirm with the OFF key. Wait until the balance automatically returns to weigh-
ing mode